Product Information

Type DH

This magnetic sensor can measure minute magnetic changes. Magnetic field changes on the order of 1/50000 of geomagnetism can be detected. It removes static magnetic field signal components such as geomagnetism and detects AC signals only.

It can be used to detect iron-based minute foreign matter in the order of 100 μm.

Magnetic noise characteristic

Magnetic noise characteristic

Product Specifications

Model No. MI-CB-1DH
Power supply voltage 5.0V (Typ.)
Magnetic fluctuation detection range 4.0 μTpp(at +/-40 μT DC field)
Sensitivity 1V/μT
Frequency response 0.1Hz to 1kHz @ -3dB
Output linearity Less than 2%FS
Noise 200pT/1σ (1Hz to 1kHz )
Substrate size 35mm×11mm
Operating current single type 15mA; multi type 6mA

Video Introduction

Price

Contact below.

Appendix

Part No. Selection Guide

Please specify the product number.

Single Type Multi Type
PCB longitudinal direction
(B direction)
MI-CB-1DH-S-B MI-CB-1DH-M-B
PCB transverse direction
(A direction)
MI-CB-1DH-S-A MI-CB-1DH-M-A

Magnetic sensing direction and sensor element position

DH single and multipin layouts

Here are examples of how to connect to a single-type MI-CB-1DH-S-A (B) and a multi-type MI-CB-1DH-M-A (B).

MI-CB-1DH-S-A(B)/MI-CB-1DH-M-A (B) terminal arrangement

Note when using multiple DH in parallel

Cautionary Statement

Notes on using more than one MI-CB-1DH

If several single-type nanotesla sensor MI-CB-1DH-S are used side by side, the respective sensors will interfere with each other, resulting in malfunction. Therefore, when two or more sensors are used together, select a MI-CB-1DH-M, which does not have an oscillator, and connect to a common oscillator MI-CB-1DH-OSC. When purchasing a multi-type MI-CB-1DH-M, an oscillator is supplied. (We also sell it.)

Connection example

Introductory Leaflet

PDF leaflet
(1.76MB)