Product Information
Type DH
This magnetic sensor can measure minute magnetic changes. Magnetic field changes on the order of 1/50000 of geomagnetism can be detected. It removes static magnetic field signal components such as geomagnetism and detects AC signals only.
It can be used to detect iron-based minute foreign matter in the order of 100 μm.
Magnetic noise characteristic
Product Specifications
Model No. | MI-CB-1DH |
---|---|
Power supply voltage | 5.0V (Typ.) |
Magnetic fluctuation detection range | 4.0 μTpp(at +/-40 μT DC field) |
Sensitivity | 1V/μT |
Frequency response | 0.1Hz to 1kHz @ -3dB |
Output linearity | Less than 2%FS |
Noise | 200pT/1σ (1Hz to 1kHz ) |
Substrate size | 35mm×11mm |
Operating current | single type 15mA; multi type 6mA |
Video Introduction
Price
Contact below.
Appendix
Part No. Selection Guide
Please specify the product number.
Single Type | Multi Type | |
---|---|---|
PCB longitudinal direction (B direction) |
MI-CB-1DH-S-B | MI-CB-1DH-M-B |
PCB transverse direction (A direction) |
MI-CB-1DH-S-A | MI-CB-1DH-M-A |
Magnetic sensing direction and sensor element position
DH single and multipin layouts
Here are examples of how to connect to a single-type MI-CB-1DH-S-A (B) and a multi-type MI-CB-1DH-M-A (B).
Note when using multiple DH in parallel
Cautionary Statement
Notes on using more than one MI-CB-1DH
If several single-type nanotesla sensor MI-CB-1DH-S are used side by side, the respective sensors will interfere with each other, resulting in malfunction. Therefore, when two or more sensors are used together, select a MI-CB-1DH-M, which does not have an oscillator, and connect to a common oscillator MI-CB-1DH-OSC. When purchasing a multi-type MI-CB-1DH-M, an oscillator is supplied. (We also sell it.)
Connection example
Introductory Leaflet
PDF leaflet(1.76MB)